MaxCS 7.5 New Features Guide Page 20 of 22
IP extensions for the following devices are added to the Trusted SIP Device list automatically:
AltiGen IP Phone
3rd Party SIP Device
IPTalk
To enable protection,
1. In MAXCS Administrator, open Boards view and double-click SIPSP.
2. Select Board Configuration > Advanced Configuration.
3. Check Block Unauthorized SIP Invite and click OK.
SightMax Version Setting
MaxCS 7.5 includes a new field for the SightMax Integration application. The version number that is entered will be
checked when the system connects to a SightMax server.
This field is located on the SightMax tab of the integration application.
Repeating Recording Tone
A new field in release 7.5 allows workgroups to set a repeating recording tone. When this is set, workgroup calls
beep once every 15 seconds.
Note: This feature works only when one or both endpoints are SIP; for example, from a PRI trunk to a SIP
extension.
To configure this repeating tone,
1. In MAXCS Administrator, select Call Center > Workgroup Configuration.
2. Select the workgroup.
3. On the General tab, set Recording Tone to Insert Repeating Recording Tone and click OK.