Extension and Workgroup Configuration
AltiWare OE System Installation & Administration Manual 201
Extension and
Workgroup
Configuration
Configure the following hardware extension-specific features:
Caution: Use caution in setting the Receiver Gain or the
Transmission Attenuation. If either setting is too high, the
result will be distortion in voice quality.
Triton Analog Station Line Properties
If you select a Triton Analog Station Board extension and click the Line
Properties button, you’ll see the Triton Analog Station Line Properties
dialog box. Note that you can use the Apply to… button to apply these
hardware settings to one, some, or all ports on the board. Using Apply to
is discussed “Apply or Apply To…?” on page 190.
Parameter Description
Message Waiting
Signal Type
Type of Message Waiting indicator for the phone set:
•None.
Voltage—voltage-based indicator.
FSK—Frequency Shift Keying indicator.
Tone—tone-based indicator.
Caller ID Signal
Format
Message format with which to send Caller ID
information:
•None
SDMFSingleDataMessageFormatfor
supporting and sending a single data type, such as
phone numbers.
MDMFMultipleDataMessageFormatfor
supporting and sending multiple data types, such
as name and number information.
Receiver Gain/
Transmission
Attenuation
Incoming and outgoing volume for every
extension. Unlike the Quantum board, these
slidesettingshave positive and negative values.
Both defaults are 0 decibels.