Triton Analog Trunk GS/LS Properties
MAXCS ACM 6.5 Administration Manual 143
Figure 13. Setting trunk In Call Routing to an AA
5. Call from one trunk to the testing reference trunk. You should hear a 1kHz tone
playing at the originating side.
6. While the tone is playing, measure the Rx Level at the trunk that is making the
outgoing call.
If the reading is less than -6 dB, for example -3 dB, take the following steps to
attenuate the gain for the Triton Analog Trunk to IP phone connection:
a. Go to VoIP Board configuration and click the Advance button.
b. Set the Transmitting gain to IP Extension to 3 for the Triton Analog Trunk. (Do
NOT change the gain in the trunk property of the Triton Analog Trunk Board,
since it may impact the echo canceller performance. If the reading is -6 dB to -
14 dB, for example, -12dB, no change is needed.
If the reading is -15 dB to -18dB, take the following steps to increase the gain for
the Triton Analog Trunk to IP phone connection:
a. Go to VoIP Board configuration and click the Advance button.
b. Set the Transmitting gain to IP Extension to 9 for the Triton Analog Trunk. (Do
NOT change the gain in the trunk property of the Triton Analog Trunk Board,
since it may impact the echo canceller performance.)
Vista de página 156
1 2 ... 152 153 154 155 156 157 158 159 160 161 162 ... 501 502

Comentários a estes Manuais

Sem comentários

Epson Large format media user manuals

Starting on S

Click on an alphabet below to scroll to the full list of models starting with that letter

Models Document Type
S041220
Datasheet   Epson Presentation Matte Paper - 44" x 82', 2 pages
S041228
Datasheet   Epson Semigloss Paper Heavyweight - A1 - 24" x 82', 2 pages
S045039
Datasheet   Epson Exhibition Fiber Paper 13" x 19", 1 pages