MAXCS ACM 6.5 Administration Manual 461
Ecuador MFC-LME Set calling part category: 2
[The switch doesn't support caller ID transmission]:
Incoming sequence: DID/DNIS
In-call signaling (depend on how many DID digits):
For 3-digit DID, set to (113)1
For 4-digit DID, set to (1113)1
For 5-digit DID, set to (11113)1
For 6-digit DID, set to (111113)1
For 7-digit DID, set to (1111113)1
For 8-digit DID, set to (11111113)1
Korea MFC-R2 Set calling part category: 1
[The switch doesn't support caller ID transmission]:
Incoming sequence: DID/DNIS
In-call signaling (depend on how many DID digits):
For 3-digit DID, set to (113)6
For 4-digit DID, set to (1113)6
For 5-digit DID, set to (11113)6
For 6-digit DID, set to (111113)6
For 7-digit DID, set to (1111113)6
For 8-digit DID, set to (11111113)6
Mexico / Teléfonos de
Mexico
Set calling part category: 2
[Assume no caller ID provided] :
Incoming sequence: DID/DNIS
In-call signaling (depend on how many DID digits):
For 3-digit DID, set to (113)1
For 4-digit DID, set to (1113)1
For 5-digit DID, set to (11113)1
For 6-digit DID, set to (111113)1
For 7-digit DID, set to (1111113)1
For 8-digit DID, set to (11111113)1
[Assume caller ID provided]:
Incoming sequence (same as above shown):
DID/DNIS * Caller ID
In-call signaling (depend on how many DID digits):
For 3-digit DID, set to (116)*(K)31
For 4-digit DID, set to (1116)*(K)31
For 5-digit DID, set to (11116)*(K)31
For 6-digit DID, set to (111116)*(K)31
For 7-digit DID, set to (1111116)*(K)31
For 8-digit DID, set to (11111116)*(K)31